Amphenol Wilcoxon Capteurs de vibrations Top exit, 105 C, 4-20mA sensor proportional to velocity, RMS, 0.5 IPS full-scale, 1/4-28 tapped hole, 2-pin MIL-C-5015 connector 11En stock
Min. : 1
Mult. : 1

Flange Mount PCC420V
Amphenol Wilcoxon Capteurs de vibrations Top exit, 85 C, 4-20 mA ( 5% @ full scale) proportional to Velocity, Equivalent Peak, 1.0 ips (25.4 mm/sec), MIL-C-5015 connector. 4En stock
Min. : 1
Mult. : 1

100 mV/g Analog Chassis Mount
Amphenol Wilcoxon Capteurs de vibrations Top exit, 105 C, 4-20 mA ( 5% @ full scale) proportional to Velocity, Equivalent Peak, 0.5 ips (12.7 mm/sec), 1/4-28 mounting hole (stud included), MIL-C-5015 connector. 3En stock
Min. : 1
Mult. : 1

Analog
Amphenol Wilcoxon Capteurs de vibrations Top exit, 85 C, 4-20 mA ( 5% @ full scale) proportional Velocity, RMS, 1.0 ips (25.4 mm/sec), blunt cut cable, 4 meter PVC coated leads standard, add 25.00, up to 75 meters. 2En stock
Min. : 1
Mult. : 1

100 mV/g Analog Chassis Mount
KEMET Capteurs de vibrations 3.2-5.5V 10-15kHz 10m/s2 Mag+Cable 2En stock
Min. : 1
Mult. : 1

VS
Amphenol Wilcoxon Capteurs de vibrations Top exit, 85 C, 4-20 mA ( 5% @ full scale) proportional Acceleration, Equivalent Peak, 10 g (98 m/sec2), blunt cut cable, 4 meter PVC coated leads standard, add 25.00, up to 75 meters. 2En stock
Min. : 1
Mult. : 1

100 mV/g Analog Chassis Mount
Amphenol Wilcoxon Capteurs de vibrations Certified velocity transmitter, loop-powered, 3 user-configurable measurement bands, HART protocol, MIL-C- 5015 connector 2En stock
Min. : 1
Mult. : 1
Analog PCH
Asus Capteurs de vibrations AISSENS 100AW: Advancing Condition Monitoring Vibration sensor with Wi-Fi Connectivity and Full-Scale Data Precision

Stud Mount
Amphenol Wilcoxon Capteurs de vibrations Digital Vibration Data Source, converts 4 analog accelerometer signals to MQTT protocol for AI, IIoT, cloud platforms 2En stock
Min. : 1
Mult. : 1
10 mV/g, 25 mV/g, 50 mV/g, 100 mV/g, 500 mV/g, 1000 mV/g DIN Rail VDS130
Amphenol Wilcoxon Capteurs de vibrations Top exit, 85 C, 4-20 mA ( 5% @ full scale) proportional to acceleration true peak, 1/4-28 mounting hole (stud included), MIL-C-5015 connector. ), 10 g (98 m/sec2) 2En stock
Min. : 1
Mult. : 1

Analog
Amphenol Wilcoxon Capteurs de vibrations Top exit, 85 C, 4-20 mA ( 5% @ full scale) proportional to Velocity, RMS, 2.0 ips (50.8 mm/sec), MIL-C-5015 connector. 2En stock
Min. : 1
Mult. : 1

Analog
Amphenol Wilcoxon Capteurs de vibrations Compact vibration transmitter, 4-20 mA vibration sensor, 105C; 20g full scale, proportional to acceleration, peak; low profile, side exit 2-pin MIL-C-5015 connector, 1/4-28 captive mounting bolt 1En stock
Min. : 1
Mult. : 1
Amphenol Wilcoxon Capteurs de vibrations Compact vibration transmitter, 4-20 mA vibration sensor, 105C; 5g full scale, proportional to acceleration, RMS; ide exit 2-pin MIL-C-5015 connector, 1/4-28 captive mounting bolt 1En stock
Min. : 1
Mult. : 1
Amphenol Wilcoxon Capteurs de vibrations 4-20 mA vibration sensor, 85C; 5g full scale; 0.5 ips full scale, output proportional to velocity, peak; addition of dynamic output signal in acceleration, top exit 3-pin MIL-C-5015 connector, 1/4-28 mounting hole (stud included) 1En stock
Min. : 1
Mult. : 1
Amphenol Wilcoxon Capteurs de vibrations Compact vibration transmitter, 4-20 mA vibration sensor, 105C; 50mm/sec full scale, proportional to velocity, RMS; top exit 4-pin M12 connector, 1/4-28 mounting hole (stud included) 1En stock
Min. : 1
Mult. : 1
Amphenol Wilcoxon Capteurs de vibrations Compact vibration transmitter, 4-20 mA vibration sensor, 105C; 10 g full scale, proportional to acceleration, RMS; top exit 4-pin M12 connector, 1/4-28 mounting hole (stud included) 1En stock
Min. : 1
Mult. : 1
Amphenol Wilcoxon Capteurs de vibrations Top exit, 105 C, 4-20 mA ( 5% @ full scale) proportional to Velocity, Equivalent Peak, 5.0 ips (127 mm/sec), 1/4-28 mounting hole (stud included), MIL-C-5015 connector. 2En stock
Min. : 1
Mult. : 1

100 mV/g Analog Chassis Mount
Molex Capteurs de vibrations Road Noise Cancellation RNC Sensor Assembly 215En stock
Min. : 1
Mult. : 1

Digital 204749
Amphenol Wilcoxon Capteurs de vibrations Compact vibration transmitter, 4-20 mA vibration sensor, 105C; 1.0 ips full scale, proportional to velocity, RMS; low profile, side exit 4-pin M12 connector, M6 captive mounting bolt 1En stock
Min. : 1
Mult. : 1
Amphenol Wilcoxon Capteurs de vibrations Compact vibration transmitter, 4-20 mA vibration sensor, 105C; 10mm/sec full scale, proportional to velocity, RMS; top exit 2-pin MIL-C-5015 connector, 1/4-28 mounting hole (stud included) 1En stock
Min. : 1
Mult. : 1

Amphenol Wilcoxon Capteurs de vibrations 1En stock
Min. : 1
Mult. : 1

Amphenol Wilcoxon Capteurs de vibrations Top exit, 85 C, 4-20 mA ( 5% @ full scale) proportional to Acceleration, RMS, 5 g (49 m/sec2), Dynamic Acceleration -100 mV/g, (10.2 mV/m/sec2), 1/4-28 mounting hole (stud included), 3 pin MIL-C-5015 connector. 1En stock
Min. : 1
Mult. : 1

100 mV/g Analog Chassis Mount
Amphenol Wilcoxon Capteurs de vibrations Top exit, 105 C, 4-20 mA ( 5% @ full scale) proportional to acceleration or velocity; peak or rms, 1/4-28 mounting hole (stud included), MIL-C-5015 connector. Acceleration, Equivalent Peak, = 5 g (49 m/sec2) 1En stock
Min. : 1
Mult. : 1

Analog
Amphenol Wilcoxon Capteurs de vibrations 1En stock
Min. : 1
Mult. : 1

100 mV/g Analog Screw Mount
Amphenol Wilcoxon Capteurs de vibrations 1En stock
Min. : 1
Mult. : 1