MCS1806 Hall-effect Current Sensors

Monolithic Power Systems (MPS) MCS1806 Hall-effect Current Sensors are 3kVRMS isolated current sensors with 500VRMS working voltage and ±2.5% accuracy. These linear Hall-effect current sensors for AC or DC current sensing incorporate differential Hall arrays that cancel out any stray magnetic fields. The MCS1806 current sensors feature ±5A to ±50A bidirectional range, adjustable bandwidth up to 100kHz, and ratio-metric outputs from the supply voltages. These Hall-effect sensors are available in SOIC-8 packages, which are factory-trimmed for accuracy and offer no magnetic Hysteresis. The MCS1806 Hall-effect current sensors are ideally used in multi-phase inverters, motor controls, automotive systems, Switch-Mode Power Supplies (SMPSs), over-current fault protection, and load detection and management.

Résultats: 23
Sélectionner Image Référence Fab. Description Fiche technique Disponibilité Prix (EUR) Filtrer les résultats dans le tableau par prix unitaire basé sur votre quantité. Qté. RoHS Modèle de ECAO Courant nominal Type de capteur Temps de réponse Précision Plage de fréquences Tension d'alimentation de fonctionnement Type de sortie Température de fonctionnement max. Température de fonctionnement min. Package/Boîte Tension d’alimentation - Max. Tension d’alimentation - Min. Type
Monolithic Power Systems (MPS) Détecteurs de courant enfichables 5V Hall current sensor. 2.5% accuracy. 3kV Isolation 968En stock
Bande coupée
3,20 €
2,86 €
2,58 €
2,49 €
Bobine
1,98 €
Min. : 1
Mult. : 1
: 500
30 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Détecteurs de courant enfichables 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation 2.424En stock
Bande coupée
3,20 €
2,86 €
2,58 €
2,49 €
Bobine
2,02 €
Min. : 1
Mult. : 1
: 500
40 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Détecteurs de courant enfichables 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation 5En stock
Bande coupée
3,84 €
3,37 €
2,89 €
2,58 €
2,42 €
Bobine
2,20 €
Min. : 1
Mult. : 1
: 500
30 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Détecteurs de courant enfichables 5V Hall current sensor. 2.5% accuracy. 3kV Isolation 337En stock
Bande coupée
3,20 €
2,86 €
2,58 €
2,49 €
Bobine
2,11 €
Min. : 1
Mult. : 1
: 500
40 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Détecteurs de courant enfichables 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation 7.468En stock
20.000Sur commande
Bande coupée
2,91 €
2,60 €
2,35 €
2,26 €
Bobine
1,86 €
Min. : 1
Mult. : 1
: 2.500
5 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Détecteurs de courant enfichables 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation 1.538En stock
5.00004/01/2028 attendu
Bande coupée
3,50 €
3,13 €
2,82 €
2,55 €
Bobine
1,89 €
Min. : 1
Mult. : 1
: 2.500
20 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Détecteurs de courant enfichables 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation 350En stock
50001/01/2027 attendu
Bande coupée
3,39 €
3,37 €
3,13 €
2,68 €
Bobine
2,13 €
Min. : 1
Mult. : 1
: 500
5 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Détecteurs de courant enfichables 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation 40En stock
50010/05/2027 attendu
Bande coupée
3,64 €
3,14 €
2,89 €
2,58 €
2,42 €
Bobine
2,20 €
Min. : 1
Mult. : 1
: 500
20 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Détecteurs de courant enfichables 5V Hall current sensor. 2.5% accuracy. 3kV Isolation 342En stock
Bande coupée
3,20 €
2,86 €
2,58 €
2,49 €
Bobine
2,13 €
Min. : 1
Mult. : 1
: 500
5 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Détecteurs de courant enfichables 5V Hall current sensor. 2.5% accuracy. 3kV Isolation 28En stock
Bande coupée
3,64 €
3,14 €
2,89 €
2,58 €
2,42 €
Bobine
2,20 €
Min. : 1
Mult. : 1
: 500
10 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Détecteurs de courant enfichables 5V Hall current sensor. 2.5% accuracy. 3kV Isolation 99En stock
Bande coupée
3,20 €
2,86 €
2,65 €
2,46 €
Bobine
2,13 €
Min. : 1
Mult. : 1
: 500
20 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Détecteurs de courant enfichables 5V Hall current sensor. 2.5% accuracy. 3kV Isolation 177En stock
Bande coupée
3,20 €
2,86 €
2,58 €
2,49 €
Bobine
2,13 €
Min. : 1
Mult. : 1
: 500
50 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Détecteurs de courant enfichables 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation
1.00007/07/2027 attendu
Bande coupée
3,39 €
3,04 €
2,74 €
2,63 €
2,49 €
Bobine
2,20 €
Min. : 1
Mult. : 1
: 500
10 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Détecteurs de courant enfichables 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation
49808/12/2026 attendu
Bande coupée
3,39 €
3,04 €
2,74 €
2,63 €
2,49 €
Bobine
2,20 €
Min. : 1
Mult. : 1
: 500
50 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Détecteurs de courant enfichables 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation Délai de livraison produit non stocké 57 Semaines
Bande coupée
3,09 €
2,76 €
2,50 €
2,39 €
Bobine
1,86 €
Min. : 1
Mult. : 1
: 2.500
30 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Détecteurs de courant enfichables 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation Délai de livraison produit non stocké 57 Semaines
Bobine
1,86 €
Min. : 2.500
Mult. : 2.500
: 2.500
40 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Détecteurs de courant enfichables 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation Délai de livraison produit non stocké 57 Semaines
Bobine
1,86 €
Min. : 2.500
Mult. : 2.500
: 2.500
50 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Détecteurs de courant enfichables 5V Hall current sensor. 2.5% accuracy. 3kV Isolation Délai de livraison produit non stocké 57 Semaines
Bobine
1,86 €
Min. : 2.500
Mult. : 2.500
: 2.500
5 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Détecteurs de courant enfichables 5V Hall current sensor. 2.5% accuracy. 3kV Isolation Délai de livraison produit non stocké 57 Semaines
Bobine
1,93 €
Min. : 2.500
Mult. : 2.500
: 2.500
10 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Détecteurs de courant enfichables 5V Hall current sensor. 2.5% accuracy. 3kV Isolation Délai de livraison produit non stocké 57 Semaines
Bobine
2,26 €
Min. : 2.500
Mult. : 2.500
: 2.500
20 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Détecteurs de courant enfichables 5V Hall current sensor. 2.5% accuracy. 3kV Isolation Délai de livraison produit non stocké 57 Semaines
Bobine
1,86 €
Min. : 2.500
Mult. : 2.500
: 2.500
30 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Détecteurs de courant enfichables 5V Hall current sensor. 2.5% accuracy. 3kV Isolation Délai de livraison produit non stocké 57 Semaines
Bobine
1,86 €
Min. : 2.500
Mult. : 2.500
: 2.500
40 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Détecteurs de courant enfichables 5V Hall current sensor. 2.5% accuracy. 3kV Isolation Délai de livraison produit non stocké 57 Semaines
Bobine
1,96 €
Min. : 2.500
Mult. : 2.500
: 2.500
50 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect