CAS Board Mount Current Transducers

LEM CAS Board Mount Current Transducers are designed for accurate electronic measurement of DC, AC, and pulsed currents, ranging from 1.5A RMS to 75A RMS, with galvanic isolation between the primary and secondary circuits. These Fluxgate-based transducers operate on a single +5V supply, ensuring low offset and gain drift. With a measuring range extending up to three times the nominal primary current (Ipn), the transducers offer high precision and reliability for various applications. Additionally, the LEM CAS sensors are designed for PCB mounting, making them easy to integrate into electronic systems.

Résultats: 6
Sélectionner Image Référence Fab. Description Fiche technique Disponibilité Prix (EUR) Filtrer les résultats dans le tableau par prix unitaire basé sur votre quantité. Qté. RoHS Modèle de ECAO Courant nominal Type de capteur Temps de réponse Précision Plage de fréquences Tension d'alimentation de fonctionnement Type de sortie
LEM Détecteurs de courant enfichables Current Transducer CAS series. For the electronic measurement of current: DC, AC, pulsed..., with galvanic seperation between the primary and the secondary circuit. 286En stock
20024/04/2026 attendu
Min. : 1
Mult. : 1

15 A Closed Loop 300 ps 0.8 % 300 kHz 5 V Digital, Analog
LEM Détecteurs de courant enfichables Current Transducer CAS series. For the electronic measurement of current: DC, AC, pulsed..., with galvanic seperation between the primary and the secondary circuit. 443En stock
20024/03/2026 attendu
Min. : 1
Mult. : 1

25 A Closed Loop 300 ps 0.8 % 300 kHz 5 V Digital, Analog
LEM Détecteurs de courant enfichables Current Transducer CAS series. For the electronic measurement of current: DC, AC, pulsed..., with galvanic seperation between the primary and the secondary circuit. 165En stock
Min. : 1
Mult. : 1

50 A Closed Loop 300 ps 0.8 % 300 kHz 5 V Digital, Analog
LEM Détecteurs de courant enfichables Current Transducer CAS series. For the electronic measurement of current: DC, AC, pulsed..., with galvanic seperation between the primary and the secondary circuit. 598En stock
Min. : 1
Mult. : 1

6 A Closed Loop 300 ps 0.8 % 300 kHz 5 V Digital, Analog
LEM Détecteurs de courant enfichables Délai de livraison produit non stocké 14 Semaines
Min. : 200
Mult. : 200
15 A Closed Loop 300 ps 0.8 % 300 kHz 5 V Digital, Analog
LEM Détecteurs de courant enfichables Délai de livraison produit non stocké 14 Semaines
Min. : 200
Mult. : 200
25 A Closed Loop 300 ps 0.8 % 300 kHz 5 V Digital, Analog